Find help with fire door inspections for Melbourne properties.

Fire door inspection costs in Melbourne

What fire door inspections, AESMR reports, repairs and replacements cost in Melbourne in 2026, what drives the price, and how to compare quotes.

Fire door inspection in Melbourne is normally priced per door, and a published Melbourne compliance price guide puts the annual inspection at $25 to $75 per door. The same guide lists the annual essential safety measures report (AESMR) for a small commercial building at $200 to $450 per report plus GST, for the report alone. Repairs and replacements are quoted after the inspection, because nobody can price them until the defects are known. The figures here come from a published source. This site is a referral service, and the provider you engage sets the actual price.

Published price ranges

Item Published Melbourne range What it covers
Fire door inspection $25 to $75 per door Annual inspection, priced per door
AESMR, small commercial building $200 to $450 per report Preparing the report only, plus GST; each measure’s servicing is extra

Both ranges come from the whatsthedamage.com.au Melbourne fire safety compliance price guide, checked in October 2026. The guide states its prices are estimates, that the inspection figure includes GST while the report figure is quoted before GST, and that AESMRs for warehouses, industrial sites and multi-storey or strata buildings are priced individually. Treat the ranges as a guide for checking whether a quote is in the normal territory, not as a promise of what a provider will charge.

There is no reliable published figure for fire door repairs or replacement doorsets in Melbourne. Those depend on the fault, the doorset, the wall it sits in and the access, so they are quoted per door once the inspection report exists.

What drives the price of a fire door inspection?

Door count. Per-door pricing means the total scales with the register. A three-storey walk-up might have a handful of doors; a residential tower can have several on every floor plus the car park.

Doors inside lots. Where apartment entry doors are fire or smoke doors under the building’s approvals, each one needs access. Every unit that cannot be reached on the day can mean a return visit. Sending proper notices to occupiers beforehand helps avoid paying for return visits.

Access conditions. Loading dock bookings, induction requirements, lift restrictions and after-hours work for trading premises all add time.

First visit or repeat visit. A building that has never had a door register needs one built: every door located, photographed, numbered and matched to the approvals. That first visit takes longer than a repeat inspection against an existing register.

Paperwork quality. If the occupancy permit, maintenance determination or schedule is missing, someone has to work out which doors are required. Getting a building surveyor to prepare a maintenance schedule is a separate cost but makes every later inspection cleaner.

Bundling. Many buildings have fire doors inspected on the same visit as other essential safety measures, such as exit lights and extinguishers. Bundled pricing can be cheaper, but check the door component is itemised.

What is included in an inspection price?

Usually included in an inspection price Usually extra
Operating each door and checking closing and latching Repairs, parts and replacement closers
Checking leaf, frame, hinges, seals and hold-open devices Replacement doorsets and frames
Recording results and defects per door Return visits for doors not accessible on the day
A written report or door register Preparing the AESMR itself, unless quoted
Photos of defects Building surveyor fees for maintenance schedules or approvals

Ask each provider to state which side of this table each item falls on. A low inspection price that leaves out the report or defect photos is not the cheaper option once the AESMR is due.

Repair and replacement costs

Once the inspection is done, ask for repair quotes that follow the defect list line by line, so you can see the price per door and per fault. Typical lines are closer replacement, hinge and latch work, seal replacement and re-hanging. For the work itself, see fire door repairs. Doorsets that have been damaged or cannot be identified need a full replacement, covered under fire door replacement; quotes should name the doorset system and say whether the frame is being replaced.

How should you compare fire door quotes?

  1. Same scope. Give every provider the same door list, building approvals and access details, so the quotes are priced on the same basis.
  2. Per-door and total. Ask for both, plus any minimum charge.
  3. Report format. Ask for a sample report. It should show each door’s location, result, defects and photos, and be usable for the owner’s AESMR.
  4. Who inspects. Ask what accreditation or training the inspector holds for fire and smoke doors. FPA Australia’s Inspect and Test accreditation has a category for fire and smoke doors.
  5. Defect pricing. Ask whether common repairs will be priced as a schedule of rates in advance, or quoted after the report.
  6. Timing against the AESMR date. Check the provider can inspect and leave time for repairs before the report is due.

Red flags in a quote

  • A price for “compliance” with no door count or door list.
  • No mention of a written report or defect register.
  • A promise that every door will pass, before anyone has seen them.
  • An offer to sign the AESMR for the owner without written authority. The Building Regulations 2018 require the owner to sign it.
  • Advice to remove a closer or leave a door open because it is “only a smoke door”.
  • Replacing doors with no mention of the doorset system or the standard, AS 1905.1.

Costs of not doing it

The Building and Plumbing Commission warns that non-compliance can bring an infringement notice from the council or fire authority, and possible prosecution with larger fines. Missing records are a separate problem: the owner must be able to produce up to 10 years of AESMRs and the maintenance records on 24 hours’ notice.

Local price factors

Towers in the Melbourne CBD and Docklands involve the most access planning. Older blocks in St Kilda more often need a first door register, and conversions in Fitzroy can need extra time to identify doors.

Next step

Put together the door count, the approvals and the AESMR due date, then ask for fire door inspection quotes so providers can price the same scope.

Send a job enquiry

Frequently asked questions

Why is fire door inspection charged per door?

Each door has to be found, operated, checked and recorded, so time on site tracks the door count. Many providers also have a minimum charge for small buildings, so ask for both the per-door rate and the total.

Are fire door repairs included in the inspection price?

Normally not. The inspection finds and records defects, and repairs are quoted separately once the defect list exists. Some providers offer a schedule of rates for common repairs.

Is the AESMR included when we pay for fire door inspections?

Not always. The published Melbourne figure for the report covers preparing the report only. Ask whether a quote includes the report, the door register, or both.

Why do quotes for the same building differ so much?

Providers often price different scopes. One may include a door register, photos and a return visit for missed doors, another may not. Giving every provider the same door list and approvals is the simplest way to compare.

Does after-hours work cost more?

It often does, because of access and labour costs. Shops, offices and venues that cannot have doors worked on during trading should mention this in the enquiry so it is priced from the start.