Find help with fire door inspections for Melbourne properties.

Fire door replacement and installation

Replacing a damaged or non-compliant fire door in a Melbourne building: when a new doorset is needed, AS 1905.1, approvals, and the records to keep.

A fire door needs replacing when the leaf or frame is damaged in a way a repair cannot make good, or when nobody can show the door was ever a fire-rated doorset. The replacement should be a complete fire-resistant doorset, installed so it performs as the building’s approvals require, with paperwork that lets the next inspector identify it. Through this site, an enquiry goes to an independent provider who quotes, supplies and installs, and the contract is with that provider.

Illustrative photo for Fire door replacement and installation

When does a fire door need replacing?

Inspectors recommend replacement rather than repair when:

  • the leaf has holes, splits or impact damage that go into the core
  • the frame is bent, loose or has pulled away from the wall
  • glazing in a fire door has been changed to ordinary glass
  • a solid door has been swapped in with no evidence it is fire rated
  • the leaf has been cut down or extended to suit new flooring
  • identification has been removed and the door’s origin cannot be traced

Doors to bin rooms, car parks, plant rooms and fire stairs see the hardest use. In apartment buildings, entry doors from units into common corridors are worth checking against the building’s approvals, because a resident may have replaced one without asking.

What standard applies to a new fire door?

AS 1905.1 is the Australian Standard for fire-resistant doorsets. Its published scope covers the construction and installation of doorsets that protect openings in walls and partitions required to resist the passage of fire, including transom panels inside the door frame. Fire resistance is tested to AS 1530.4, the test method for fire-resistance of building elements. The NCC and the building’s approvals decide where fire doors are required and what rating each needs.

What this means for an owner: a fire door is a tested system of leaf, frame, hinges, closer, latch and seals. Buying a fire-rated leaf and hanging it in the old frame with whatever hardware is on hand is not the same thing.

Options compared

Option Suits Things to settle first
Replace the leaf only Frame sound and compatible with the new leaf Whether the doorset system allows leaf-only replacement
Replace the complete doorset Frame damaged or of unknown origin Wall type, making good around the new frame, access during the work
Upgrade hardware with the new door Heavy-traffic doors Closer and hinge specification suited to the door weight
Change door type or location Layout changes, new tenancy fit-outs Building surveyor advice before ordering

Do you need a permit to replace a fire door?

A like-for-like swap is the simplest case, and anything that changes the door needs more care. The Building and Plumbing Commission advises owners planning work that alters an existing building to check with a municipal or private building surveyor, because it may affect the essential safety measures. Moving a door, changing its rating, adding glazing or adding an electromagnetic hold-open all fall into that category. A careful provider will ask what the approvals say before ordering, and will tell you when a building surveyor needs to be involved.

Under the Building Regulations 2018, an owner has to make sure a required safety measure stays in its approved place, other than while it is being inspected, tested or maintained. Leaving a doorway open for days while a door is on order is a risk the provider should plan around.

What the provider needs to quote

  1. The inspection report and the door reference for each door to be replaced.
  2. Photos of both faces of the door, the hinges, the closer and the frame head.
  3. The wall type around the frame, if known: masonry, concrete or a lightweight fire-rated wall.
  4. The fire resistance level shown on the approvals or the existing label.
  5. Opening hours and any restrictions on noise or lift use.

What installation involves

The old leaf and, where needed, the frame are removed. The new frame is fixed and the gap to the wall sealed in the manner the doorset system specifies. The leaf is hung on the specified hinges, the closer and latch are fitted and adjusted, and seals are installed where the door also serves as a smoke door. The door is then tested for closing and latching. Expect the provider to leave a record naming the door location, the doorset and its identification, and the hardware fitted.

What a careful installer will refuse

  • Fitting a fire-rated leaf into a frame that is not part of a compatible doorset.
  • Cutting a fire door to clear new floor coverings without confirming the door’s limits.
  • Adding a vision panel to an existing fire door on site.
  • Leaving the door without a closer while waiting for parts.

Cost

Replacement is quoted per door once the doorset type, frame work and access are known, so no single published figure is useful here. The Melbourne fire door cost guide covers what drives the price and how to compare quotes. Doors with hardware faults only are usually cheaper to fix, as described under fire door repairs.

Where replacements come up

Retail and office fit-outs in Docklands and the CBD generate replacements when tenancies change. In older blocks in St Kilda, replacements often follow an inspection that cannot identify doors fitted decades ago.

What to do next

Gather photos and the inspection findings, then request a quote to replace fire doors with the number of doors and the building address.

Send a job enquiry

Frequently asked questions

How do I know if a door is a fire door?

Check the building approvals, which list required fire doors, and look for an identification label or tag on the door edge or frame. A solid timber door with no paperwork or label cannot be assumed to be fire rated.

Can I just replace the door leaf and keep the frame?

Sometimes. It depends on whether the frame is sound and whether the doorset system allows a leaf to be fitted to the existing frame. Ask the provider to confirm compatibility in writing before ordering.

Does replacing a fire door need a building permit?

Changing a door's rating, size, type or location is a change to an essential safety measure, so ask a municipal or private building surveyor before work starts. The provider should tell you when that step is needed.

How long does a replacement fire door take?

Doorsets are often made or ordered to suit the opening, so there is usually a lead time before installation. Ask the provider for the lead time and how the opening will be protected until the new door is fitted.

Which standard covers new fire doors?

AS 1905.1 covers fire-resistant doorsets, including their construction and installation. Fire resistance testing is done under AS 1530.4. The building's approvals and the NCC decide where fire doors are required.